WEBVTT 1 00:00:01.000 --> 00:00:04.500 Whether you're replacing an existing controller or installing one 2 00:00:04.500 --> 00:00:08.720 for the first time, Rainbird helps you take control over your landscape. 3 00:00:09.860 --> 00:00:13.900 To get started, choose a mounting location on a wall within 6 feet 4 00:00:13.900 --> 00:00:17.380 of an AC power outlet and away from major appliances or air 5 00:00:17.380 --> 00:00:18.880 conditioners. 6 00:00:19.120 --> 00:00:21.230 If you're replacing an existing controller, 7 00:00:21.470 --> 00:00:23.640 take a photo of the wiring details. 8 00:00:23.930 --> 00:00:26.980 This will be a useful reference when installing the new controller. 9 00:00:27.550 --> 00:00:30.470 Be sure to also take note of your existing settings, 10 00:00:30.730 --> 00:00:34.670 including start times, run times and watering days for each 11 00:00:34.670 --> 00:00:35.630 station. 12 00:00:35.630 --> 00:00:38.220 You'll use this information later when you program 13 00:00:38.220 --> 00:00:39.590 the new controller. 14 00:00:39.590 --> 00:00:43.740 Unplug the power cord from the AC outlet and disconnect any valve, 15 00:00:43.780 --> 00:00:45.280 sensor or pump start wires. 16 00:00:46.140 --> 00:00:49.600 If your old controller is hardwired directly into the power supply 17 00:00:49.600 --> 00:00:51.870 box, check your local building codes for guidance. 18 00:00:52.000 --> 00:00:52.860 guidance. 19 00:00:52.860 --> 00:00:56.250 Any permanent connection should be made by a licensed electrical 20 00:00:56.250 --> 00:00:59.630 contractor in accordance with the requirements of the National 21 00:00:59.630 --> 00:01:02.590 Electrical Code and other state and local codes. 22 00:01:03.390 --> 00:01:07.610 Next, remove the mounting screws and take the old unit off the wall. 23 00:01:08.070 --> 00:01:11.120 To mount your new controller, use the keyhole slot 24 00:01:11.120 --> 00:01:13.870 to hang the controller securely on the mounting screw. 25 00:01:14.390 --> 00:01:17.470 Remove the wire bay cover and drive a second screw 26 00:01:17.470 --> 00:01:19.630 through the open hole and into the wall. 27 00:01:21.010 --> 00:01:22.800 Route all field wires through the opening 28 00:01:22.800 --> 00:01:24.190 at the bottom of the controller. 29 00:01:24.190 --> 00:01:27.050 Do not route the valve wires through the same opening 30 00:01:27.050 --> 00:01:28.550 as the power wires. 31 00:01:28.790 --> 00:01:32.500 Do not remove the yellow jumper wire unless you are installing 32 00:01:32.540 --> 00:01:34.040 a rain-free sensor. 33 00:01:34.300 --> 00:01:37.360 Next, attach the common wire, which is usually 34 00:01:38.040 --> 00:01:40.120 white, to the common terminal marked C. 35 00:01:40.840 --> 00:01:44.350 Using the photo of the wiring details from your old controller, 36 00:01:44.670 --> 00:01:48.890 connect one wire from each valve to one of the numbered zone terminals 37 00:01:48.890 --> 00:01:50.390 on the controller itself. 38 00:01:50.730 --> 00:01:54.570 Depending on your specific model, this controller can accommodate up 39 00:01:54.570 --> 00:01:58.680 to eight independent stations, but be sure to connect only one valve 40 00:01:58.680 --> 00:02:00.660 wire to each zone terminal. 41 00:02:01.480 --> 00:02:05.160 Once you have all wires connected, record which valve wires 42 00:02:05.160 --> 00:02:08.170 are associated with their station on the programming chart that was 43 00:02:08.170 --> 00:02:09.670 supplied with the controller. 44 00:02:10.200 --> 00:02:13.150 Reference this chart when programming your watering schedule. 45 00:02:14.400 --> 00:02:18.620 After you've checked all wiring connections, it's time to apply power 46 00:02:18.620 --> 00:02:19.970 to the controller. 47 00:02:19.970 --> 00:02:22.580 If you've mounted your true controller indoors, 48 00:02:22.980 --> 00:02:26.580 connect the power cord wires to the 24VAC terminals 49 00:02:26.740 --> 00:02:29.500 prior to plugging the transformer into a power outlet. 50 00:02:30.200 --> 00:02:32.580 If your new controller is installed on an exterior facade, 51 00:02:32.600 --> 00:02:34.580 where it will be exposed to the elements, 52 00:02:35.360 --> 00:02:38.320 the Outdoor model comes with a pre-installed 6-foot 53 00:02:38.320 --> 00:02:42.200 power cord so it can be installed inside or outside if plugged 54 00:02:42.200 --> 00:02:44.080 into a weatherproof external outlet. 55 00:02:45.740 --> 00:02:49.350 Next, reinstall the wire bay cover and plug in the controller power 56 00:02:49.350 --> 00:02:50.400 cord. 57 00:02:50.400 --> 00:02:53.820 To ensure the controller is connected properly, turn the dial 58 00:02:53.820 --> 00:02:57.860 to manual station and run each valve for a short period of time 59 00:02:57.860 --> 00:03:00.740 to ensure that each station is actively watering. 60 00:03:01.320 --> 00:03:05.050 Now that your True irrigation controller is securely mounted, you 61 00:03:05.050 --> 00:03:07.300 can program your new True controller. 62 00:03:08.440 --> 00:03:09.320 Happy watering!