WEBVTT 1 00:00:02.260 --> 00:00:04.140 In this lesson, we'll introduce 2 00:00:04.140 --> 00:00:05.640 our turbojet family. 3 00:00:06.090 --> 00:00:07.920 Turbojets are our negative air 4 00:00:07.920 --> 00:00:09.870 machines, and they come in three 5 00:00:09.870 --> 00:00:11.190 models. 6 00:00:11.190 --> 00:00:14.800 The Turbojet Max, the Turbojet Max 2, 7 00:00:15.220 --> 00:00:17.980 and our top of the line Turbojet Super Max. 8 00:00:19.090 --> 00:00:21.100 All turbojets have the same body, 9 00:00:21.590 --> 00:00:23.090 wheels and filters. 10 00:00:23.570 --> 00:00:25.040 The differences are in the power 11 00:00:25.040 --> 00:00:26.540 specifications. 12 00:00:26.930 --> 00:00:28.430 Think of each one like a car. 13 00:00:28.940 --> 00:00:31.110 The Turbojet Max is like a four cylinder. 14 00:00:31.810 --> 00:00:35.170 The MAX II is like an 8-cylinder and the SUPER 15 00:00:35.170 --> 00:00:37.570 MAX is a 12-cylinder beast. 16 00:00:38.410 --> 00:00:40.730 At Aircare, our experience in duct cleaning 17 00:00:40.790 --> 00:00:42.820 has allowed us to design our turbojets 18 00:00:43.030 --> 00:00:44.530 to be easy to use. 19 00:00:46.050 --> 00:00:48.800 Turbojets can be easily moved around corners, 20 00:00:49.270 --> 00:00:51.390 upstairs, and down to basements. 21 00:00:53.000 --> 00:00:55.670 The back wheels are a heavy-duty 12-inch 22 00:00:55.670 --> 00:00:56.630 wheel. 23 00:00:56.630 --> 00:00:59.420 The front swivel casters are lockable to keep 24 00:00:59.420 --> 00:01:01.380 the unit in place and allows 25 00:01:01.440 --> 00:01:03.330 easy maneuverability when needed. 26 00:01:04.970 --> 00:01:07.690 All of our wheels are non-marking, so those 27 00:01:07.690 --> 00:01:10.140 homes with white carpeting will not be an issue. 28 00:01:10.870 --> 00:01:12.660 But make sure you wipe down the wheels 29 00:01:12.660 --> 00:01:14.160 for any dirt before entering. 30 00:01:15.380 --> 00:01:17.200 Each turbojet has an opening 31 00:01:17.200 --> 00:01:19.830 at the top and a mounting collar to connect 32 00:01:19.830 --> 00:01:21.790 your 12-inch Mylar hose at one end. 33 00:01:23.580 --> 00:01:25.360 To attach the other end to the vent, 34 00:01:25.650 --> 00:01:28.300 you can use the supplied collar to attach the hose 35 00:01:28.500 --> 00:01:31.160 to the ceiling with tape or have a second worker 36 00:01:31.230 --> 00:01:32.730 hold it in place. 37 00:01:32.900 --> 00:01:35.470 However, we do have a much better solution, 38 00:01:35.990 --> 00:01:38.750 our expandable pogo pole hose adapter. 39 00:01:39.870 --> 00:01:41.980 This will allow hands-free connection 40 00:01:41.980 --> 00:01:43.980 between the turbojet and the vent. 41 00:01:45.420 --> 00:01:48.120 It also has an opening to use the sidewinder 42 00:01:48.120 --> 00:01:49.740 or air whisk reverse valve to clean. 43 00:01:51.530 --> 00:01:53.420 Each turbojet has four latches 44 00:01:53.630 --> 00:01:55.570 that allow easy access to the filters. 45 00:01:56.910 --> 00:01:59.860 The turbojets come with three filters. 46 00:01:59.860 --> 00:02:01.510 When shipped, these filters will be 47 00:02:01.510 --> 00:02:04.440 packed inside your machine. 48 00:02:04.440 --> 00:02:06.360 The first stage electrostatic filter 49 00:02:06.510 --> 00:02:08.750 has a disposable pad and is mounted 50 00:02:08.750 --> 00:02:10.510 to the top section of the turbojet. 51 00:02:11.460 --> 00:02:13.800 It is held in place with metal brackets at one 52 00:02:14.290 --> 00:02:15.790 end and a clip at the other end. 53 00:02:17.170 --> 00:02:18.670 The pad in the first filter 54 00:02:18.670 --> 00:02:21.760 is disposable and can be used two to three times 55 00:02:21.760 --> 00:02:23.640 before it will need to be replaced. 56 00:02:25.040 --> 00:02:28.010 This is the first location debris will collect and it 57 00:02:28.010 --> 00:02:29.510 will be the largest debris. 58 00:02:30.250 --> 00:02:32.590 To empty after cleaning, place 59 00:02:32.590 --> 00:02:35.530 or attach a large trash bag at the top opening 60 00:02:35.530 --> 00:02:36.850 of the turbojet. 61 00:02:36.850 --> 00:02:39.740 Open the lid and as it opens debris 62 00:02:39.740 --> 00:02:41.300 will fall into the trash bag. 63 00:02:42.200 --> 00:02:44.590 Once the debris is collected, you can put 64 00:02:44.590 --> 00:02:46.090 the dirty filter in the bag. 65 00:02:47.390 --> 00:02:49.900 The second stage flex filter is embedded 66 00:02:50.030 --> 00:02:51.620 on the top of the HEPA filter frame. 67 00:02:53.030 --> 00:02:55.290 This filter is cleanable and reusable. 68 00:02:56.300 --> 00:02:58.580 To clean the filter, place the filter 69 00:02:59.330 --> 00:03:00.830 outside and use a garden hose. 70 00:03:01.720 --> 00:03:03.860 Then spray in the opposite direction 71 00:03:03.960 --> 00:03:05.460 of the airflow first. 72 00:03:06.180 --> 00:03:08.600 Then turn it around and clean the reverse. 73 00:03:09.970 --> 00:03:12.870 Once clean, let it dry and return it 74 00:03:12.870 --> 00:03:14.370 to the turbojet. 75 00:03:14.460 --> 00:03:16.980 The third stage HEPA filter is the most 76 00:03:16.980 --> 00:03:18.910 powerful filter in the unit. 77 00:03:19.920 --> 00:03:22.630 It collects debris down to 0.3 microns. 78 00:03:23.440 --> 00:03:25.840 This filter can be used for an extended period. 79 00:03:26.440 --> 00:03:28.530 Note that this filter cannot be cleaned. 80 00:03:29.340 --> 00:03:31.870 It will need to be eventually replaced two 81 00:03:31.870 --> 00:03:34.200 to four times a year, depending on use. 82 00:03:35.130 --> 00:03:37.180 How do you know it's time to replace the HEPA 83 00:03:37.180 --> 00:03:38.680 filter? 84 00:03:39.230 --> 00:03:41.270 Both the MAX II and the SUPER MAX 85 00:03:41.440 --> 00:03:43.970 have indicator lights that will glow red when 86 00:03:43.970 --> 00:03:45.930 the HEPA filter needs to be replaced. 87 00:03:46.690 --> 00:03:48.280 For the Turbojet MAX, there 88 00:03:48.280 --> 00:03:50.350 isn't a visual indicator, but if you 89 00:03:50.350 --> 00:03:53.150 suspect the airflow is not as strong as it should be, 90 00:03:53.480 --> 00:03:56.320 visually check the HEPA filter for dirt or debris. 91 00:03:57.880 --> 00:03:59.780 Now that we have reviewed the similarities 92 00:03:59.780 --> 00:04:02.170 in the turbojets, let's look at the best 93 00:04:02.170 --> 00:04:03.670 uses for each one. 94 00:04:04.310 --> 00:04:06.780 We will be discussing qubit feet per minute 95 00:04:06.780 --> 00:04:08.340 and suction lift for our machines. 96 00:04:08.840 --> 00:04:11.090 If you need a review, please watch video 97 00:04:11.090 --> 00:04:12.590 2 for more information. 98 00:04:13.760 --> 00:04:15.480 We'll start with the turbojet max. 99 00:04:16.310 --> 00:04:18.940 This unit is primarily for residential cleaning. 100 00:04:20.520 --> 00:04:22.650 The TurboJet Max has a single speed, 101 00:04:23.160 --> 00:04:28.070 1.5 horsepower motor and produces 2,500 102 00:04:28.070 --> 00:04:30.940 CFM's without a filter and 2,000 103 00:04:30.940 --> 00:04:32.440 CFM's with filters. 104 00:04:33.210 --> 00:04:35.620 The wide opening will not give you a lot of suction 105 00:04:35.620 --> 00:04:38.480 power, but you will get 2000 cfm 106 00:04:38.500 --> 00:04:40.460 of air movement, which is what you 107 00:04:40.460 --> 00:04:41.960 want with negative air cleaning. 108 00:04:43.260 --> 00:04:45.750 For smaller homes, less than 1600 109 00:04:45.750 --> 00:04:48.090 square feet, you will only need 110 00:04:48.090 --> 00:04:50.490 to place this unit in one central location. 111 00:04:51.740 --> 00:04:54.100 But for larger homes, you will need to move it 112 00:04:54.100 --> 00:04:56.260 to a second location to effectively 113 00:04:56.260 --> 00:04:57.760 clean the ducts. 114 00:04:58.820 --> 00:05:02.070 Before using the TurboJet Max, you should first test 115 00:05:02.070 --> 00:05:03.130 it. 116 00:05:03.130 --> 00:05:05.990 Attach the 12 gauge, 25 foot power cord 117 00:05:06.220 --> 00:05:07.720 to a dedicated outlet. 118 00:05:08.300 --> 00:05:10.010 This is an outlet that has nothing 119 00:05:10.010 --> 00:05:11.510 else attached to it. 120 00:05:12.070 --> 00:05:13.810 Turn on the circuit breaker switch 121 00:05:13.810 --> 00:05:15.310 on the front panel. 122 00:05:16.140 --> 00:05:17.650 Then switch the run to on. 123 00:05:18.530 --> 00:05:20.790 The Max will slowly climb to full speed. 124 00:05:21.610 --> 00:05:23.280 You are now ready for duct cleaning. 125 00:05:24.920 --> 00:05:27.430 The Turbojet Max 2 is next in our lineup. 126 00:05:28.780 --> 00:05:30.720 This comes with a one and a half horsepower 127 00:05:30.720 --> 00:05:32.830 motor, but it has two speeds. 128 00:05:34.050 --> 00:05:37.280 It can produce 3,000 CFMs without filters 129 00:05:37.620 --> 00:05:40.660 and 2,700 CFMs with filters installed. 130 00:05:41.990 --> 00:05:44.340 The Max2 can clean any home size 131 00:05:44.490 --> 00:05:46.740 and small to medium size commercial buildings. 132 00:05:48.000 --> 00:05:50.090 For single-story residential cleaning, 133 00:05:50.440 --> 00:05:52.770 you will most likely need to just place the Maxx2 134 00:05:53.110 --> 00:05:55.290 in one location to clean the entire 135 00:05:55.290 --> 00:05:56.710 residence. 136 00:05:56.710 --> 00:05:59.350 For two story structures, you will need to move 137 00:05:59.350 --> 00:06:01.360 the Maxx and the Maxx2 upstairs 138 00:06:01.360 --> 00:06:03.250 for continued cleaning. 139 00:06:03.250 --> 00:06:05.440 To set up and test the unit, place 140 00:06:05.440 --> 00:06:07.320 it at the desired location for cleaning. 141 00:06:08.500 --> 00:06:10.850 Leave the top of the unit open without the mylar 142 00:06:10.850 --> 00:06:12.350 hose attached. 143 00:06:12.400 --> 00:06:15.120 Then attach the power cord to a dedicated outlet. 144 00:06:16.440 --> 00:06:18.150 Then turn on the circuit breaker switch 145 00:06:18.430 --> 00:06:19.930 on the front panel. 146 00:06:20.400 --> 00:06:22.260 The Max 2 has a high and low setting. 147 00:06:23.300 --> 00:06:26.730 Low setting is 13 amps and the high setting is 17 148 00:06:26.840 --> 00:06:27.670 amps depending 149 00:06:27.670 --> 00:06:29.170 on the available power. 150 00:06:29.580 --> 00:06:31.080 Choose your desired setting. 151 00:06:32.370 --> 00:06:35.820 Next, set the speed to high and switch the run 152 00:06:35.820 --> 00:06:37.260 to on. 153 00:06:37.260 --> 00:06:39.780 The Max 2 will slowly spool up to full power. 154 00:06:41.540 --> 00:06:44.540 The Turbojet SuperMax is our most powerful machine. 155 00:06:45.400 --> 00:06:48.180 The SuperMax comes with a 3-horsepower, 156 00:06:48.490 --> 00:06:50.830 4-speed motor which does add an 157 00:06:50.830 --> 00:06:53.010 additional 25 pounds to the unit. 158 00:06:53.670 --> 00:06:57.030 It produces 5,000 CFMs without filters 159 00:06:57.300 --> 00:06:59.760 and 3,500 CFMs with filters. 160 00:07:00.580 --> 00:07:03.620 The SuperMax is for all residential and commercial 161 00:07:03.620 --> 00:07:05.120 cleaning. 162 00:07:05.300 --> 00:07:08.350 The SuperMax also comes with two 25 foot 163 00:07:08.410 --> 00:07:10.430 power cords which needs to be 164 00:07:10.430 --> 00:07:13.210 connected to two separate 20 amp outlets. 165 00:07:14.370 --> 00:07:16.090 The outlets must be on separate 166 00:07:16.090 --> 00:07:17.700 circuits to run the SuperMax 167 00:07:17.700 --> 00:07:19.200 at full power. 168 00:07:19.590 --> 00:07:21.090 If you only have one circuit, 169 00:07:21.340 --> 00:07:23.220 you can only use the two lower speeds. 170 00:07:24.920 --> 00:07:26.190 You can see if you're running 171 00:07:26.190 --> 00:07:28.410 on different circuits during the startup 172 00:07:28.410 --> 00:07:29.910 testing process. 173 00:07:30.470 --> 00:07:32.690 First, set the run switch to the stop position. 174 00:07:33.450 --> 00:07:35.490 Make sure the top of the turbojet does not 175 00:07:35.540 --> 00:07:38.130 have the mylar hose attached. 176 00:07:38.130 --> 00:07:39.630 Turn off both circuit breakers. 177 00:07:40.590 --> 00:07:42.020 Next, connect the two power 178 00:07:42.020 --> 00:07:44.090 cords to two separate dedicated 179 00:07:44.520 --> 00:07:45.370 outlets. 180 00:07:45.370 --> 00:07:48.060 Once the power cords are connected, turn both 181 00:07:48.060 --> 00:07:50.360 the circuit breakers on and wait five seconds. 182 00:07:51.480 --> 00:07:53.440 The motor will not run during this five 183 00:07:53.870 --> 00:07:55.370 second diagnostic check. 184 00:07:56.230 --> 00:07:58.120 The indicator light below the HEPA change 185 00:07:58.120 --> 00:07:59.720 light will shine green during 186 00:07:59.720 --> 00:08:01.790 the check if everything is good to go. 187 00:08:02.440 --> 00:08:05.010 If you see a steady or blinking red indicator, 188 00:08:05.470 --> 00:08:07.080 consult your user's manual for 189 00:08:07.080 --> 00:08:08.580 additional steps. 190 00:08:09.860 --> 00:08:12.860 After the diagnostic check is complete and everything 191 00:08:12.860 --> 00:08:15.270 is good, the SuperMAX will slowly 192 00:08:15.290 --> 00:08:16.640 start up. 193 00:08:16.640 --> 00:08:18.730 The super max is powerful and you 194 00:08:18.730 --> 00:08:21.510 will most likely need only one or two motors 195 00:08:21.510 --> 00:08:23.010 running during cleaning. 196 00:08:23.370 --> 00:08:25.320 But it's good to know for those tough jobs 197 00:08:25.540 --> 00:08:27.160 you have more power if needed.