WEBVTT 1 00:00:02.520 --> 00:00:05.040 Hisense Portable Air Conditioner Installation 2 00:00:06.560 --> 00:00:08.460 Please read and follow the instructions 3 00:00:08.460 --> 00:00:10.860 in the owner's manual before you attempt to install, 4 00:00:11.070 --> 00:00:13.820 operate, maintain, or troubleshoot your portable air 5 00:00:13.820 --> 00:00:14.720 conditioner. 6 00:00:14.720 --> 00:00:17.660 It is recommended to always place your portable air conditioner 7 00:00:17.660 --> 00:00:19.860 on a flat and level surface for optimal performance. 8 00:00:21.100 --> 00:00:24.040 Measure the install location before placing your portable air 9 00:00:24.040 --> 00:00:25.820 conditioner to ensure a proper fit. 10 00:00:26.120 --> 00:00:27.620 Caution, the unit is heavy. 11 00:00:27.900 --> 00:00:29.760 Have someone assist you with your portable air 12 00:00:29.760 --> 00:00:32.680 conditioner to help prevent product damage or personal injury. 13 00:00:33.400 --> 00:00:36.150 Take a moment to see what tools are needed for installation. 14 00:00:38.400 --> 00:00:41.760 Unbox your new portable air conditioner and remove all packaging 15 00:00:41.760 --> 00:00:43.260 materials. 16 00:00:46.920 --> 00:00:50.000 Remove the portable air conditioner from the foam base and place 17 00:00:50.000 --> 00:00:52.720 it on a flat and level surface near the install location. 18 00:00:57.360 --> 00:00:59.220 Portable air conditioner components. 19 00:00:59.780 --> 00:01:04.030 Flexible exhaust hose and foam seals, owner's manual, remote, 20 00:01:04.200 --> 00:01:05.900 quick start guide, and warranty card. 21 00:01:06.400 --> 00:01:08.460 Coupling and window exhaust adapter. 22 00:01:08.820 --> 00:01:11.740 Both have integral clips that snap onto the vent hose. 23 00:01:16.800 --> 00:01:19.190 Sliding window vent and extension panels. 24 00:01:21.860 --> 00:01:23.920 Flexible exhaust hose and adapter. 25 00:01:24.860 --> 00:01:27.760 Insert the coupling into the slot on the back of the portable air 26 00:01:27.760 --> 00:01:28.680 conditioner. 27 00:01:28.680 --> 00:01:30.860 Slide it in to lock the hose in place. 28 00:01:33.320 --> 00:01:35.900 Once secure, you can now fully retract the hose. 29 00:01:36.620 --> 00:01:38.640 Window vent panel and extensions. 30 00:01:39.040 --> 00:01:41.680 The window installation kit allows you to install the air 31 00:01:41.680 --> 00:01:45.200 conditioner in most vertical sliding windows 18 to 50 inches 32 00:01:45.200 --> 00:01:48.900 wide or horizontal sliding windows from 18 to 50 inches tall. 33 00:01:49.380 --> 00:01:52.520 Measure the length of your window and choose the vent panels that best 34 00:01:52.520 --> 00:01:53.740 fit your needs. 35 00:01:53.740 --> 00:01:56.560 Insert the vent panel assembly into the window opening 36 00:01:56.560 --> 00:02:00.100 with the pre-drilled holes facing up, and extend it to the maximum length 37 00:02:00.100 --> 00:02:01.020 of the window. 38 00:02:01.020 --> 00:02:05.040 While holding the vent panel assembly firmly in place, use a marker or pin 39 00:02:05.040 --> 00:02:06.900 to create an indicator mark at the top. 40 00:02:07.180 --> 00:02:10.560 In some cases, the pre-drilled holes may not align properly 41 00:02:10.560 --> 00:02:11.930 to the window's dimension. 42 00:02:11.930 --> 00:02:14.760 Create an indicator mark that will help ensure a proper fit. 43 00:02:15.180 --> 00:02:18.160 Use a drill and drill bit to create a matching pilot hole 44 00:02:18.160 --> 00:02:19.660 in the extension panel. 45 00:02:20.160 --> 00:02:23.260 Use the rivet to hold the window vent panel and extension panel 46 00:02:23.260 --> 00:02:25.290 together at the pre-drilled hole you marked. 47 00:02:29.930 --> 00:02:32.300 Measure and cut the long adhesive foam seals 48 00:02:32.300 --> 00:02:34.890 to match the extended length of the vent panel assembly. 49 00:02:38.990 --> 00:02:42.440 Two short foam seals are also provided to place onto each side 50 00:02:42.440 --> 00:02:43.940 of the vent panel assembly. 51 00:02:44.920 --> 00:02:47.820 Peel off the plastic on the adhesive foam seals and attach 52 00:02:47.820 --> 00:02:49.820 them directly to their respective sides. 53 00:02:50.800 --> 00:02:54.080 Reinsert the window vent panel assembly inside the window frame 54 00:02:54.080 --> 00:02:55.450 to double check the fitting. 55 00:02:55.450 --> 00:02:58.520 If more room is needed to attach the flexible exhaust hose 56 00:02:58.520 --> 00:03:01.900 adapter, add additional layers of foam seal below the vent panel 57 00:03:01.900 --> 00:03:05.020 assembly to increase the height all around the assembly for a tighter 58 00:03:05.020 --> 00:03:05.680 fit. 59 00:03:05.680 --> 00:03:09.540 After the window vent panel assembly has been properly fitted, insert 60 00:03:09.540 --> 00:03:12.010 and clamp down the window exhaust adapter as shown 61 00:03:12.010 --> 00:03:13.510 into the vent panel's opening. 62 00:03:14.640 --> 00:03:18.100 To prevent the window exhaust adapter from sliding out of the vent panel 63 00:03:18.100 --> 00:03:21.320 opening, insert the two screws provided in the exhaust adapter 64 00:03:21.320 --> 00:03:22.120 holes. 65 00:03:22.120 --> 00:03:25.080 Reinsert the vent panel assembly inside the window frame 66 00:03:25.080 --> 00:03:26.580 and close the window. 67 00:03:30.660 --> 00:03:33.660 Insert the foam insulation between the window frame to help 68 00:03:33.660 --> 00:03:35.160 reduce air gaps. 69 00:03:36.740 --> 00:03:39.700 For additional support, you can attach a window lock bracket 70 00:03:39.730 --> 00:03:42.520 to the top of a wood window frame as shown in this example. 71 00:03:43.800 --> 00:03:47.020 Retract the vent hose and allow at least 20 inches of space 72 00:03:47.040 --> 00:03:48.790 all around the portable air conditioner. 73 00:03:49.170 --> 00:03:52.040 Plug your new portable air conditioner into a grounded power 74 00:03:52.040 --> 00:03:53.950 wall outlet and press the reset button. 75 00:03:54.600 --> 00:03:57.600 For optimal performance, keep the portable air conditioner 76 00:03:57.600 --> 00:03:59.860 vents free and clear of any obstructions. 77 00:04:00.120 --> 00:04:02.560 Dual hose air conditioner quick installation. 78 00:04:03.010 --> 00:04:05.670 The dual hose portable air conditioner comes equipped 79 00:04:05.680 --> 00:04:07.180 with a dual slotted vent panel. 80 00:04:07.640 --> 00:04:10.300 After snapping the integral clips onto the vent panel, 81 00:04:10.520 --> 00:04:13.900 use the four screws to securely attach the two window exhaust 82 00:04:13.900 --> 00:04:14.890 adapters. 83 00:04:14.890 --> 00:04:21.120 For model HAP0824TWD, the two window exhaust adapters snap into the panel 84 00:04:21.120 --> 00:04:23.320 slots, eliminating the need for screws. 85 00:04:23.920 --> 00:04:26.700 Orient the exhaust adapters correctly and insert them 86 00:04:26.700 --> 00:04:28.200 into the designated slots. 87 00:04:29.230 --> 00:04:31.700 Slide the adapters until they click into place. 88 00:04:35.820 --> 00:04:39.100 Flip the extension panel and verify the exhaust adapters 89 00:04:39.100 --> 00:04:41.380 are fully inserted and seated without gaps. 90 00:04:41.860 --> 00:04:45.480 Attach the two couplings on one end of the hoses and clip the other end 91 00:04:45.480 --> 00:04:47.480 of the hoses to the exhaust adapters. 92 00:04:56.230 --> 00:04:59.440 Insert the window vent panel assembly inside the window frame 93 00:04:59.590 --> 00:05:01.090 and close the window. 94 00:05:06.000 --> 00:05:08.760 Extend the vent hose to comfortably attach it to the back 95 00:05:08.760 --> 00:05:10.410 of the dual hose portable air conditioner. 96 00:05:12.760 --> 00:05:15.100 Slide both couplings into their slots. 97 00:05:16.480 --> 00:05:18.860 Once connected, follow the same instructions 98 00:05:18.860 --> 00:05:19.410 as before.